Pelco Manual C1472M-C (10/05) 5
Camera Mounting
1. Attach the camera to the sled with the 1/4-20 Phillips-head screws that are provided in
the parts bag. Attach the camera so that it is inside the “U” shape of the sled.
2. Install the sled and camera in the enclosure:
a. If the camera’s lens is varifocal, extend the lens to its maximum length. This will
ensure that the lens has enough clearance and will not come in contact with the
window during scene setup.
b. Place the sled over the mounting screws in the enclosure. Depending on the height
required for the camera inside the enclosure, the sled can be installed so that its
base faces either the top or the bottom of the enclosure.
c. Slide the camera sled forward until the lens almost touches the window.
d. Tighten the two 10-32 Phillips-head screws and secure the camera sled to the rail.
Proceed to the
Wiring Camera and Lens
section.
Wiring Camera and Lens
1. Bring a coaxial cable into the enclosure and connect the camera’s video output. Refer to
Table B for cable distances.
2. Bring wiring into the enclosure for camera synchronization and motorized lens if you are
going to use these functions. Connect the wiring to the circuit board. (Refer to Figures 1
and 2.)
HS4514 Model Only - Connect the wiring from the lens controller directly to the lens
connection.
HS4514-1/-2/-3 Models with Heater - Refer to Figures 1 and 2 and wire the
motorized zoom lens control as follows:
a. Connect or wire the lens control from the camera to the LENS or LENS CONTROL
connector on the circuit board.
GNDNTHI10987654321
AC IN
TB2
TB1
HIGH
INPUTS
LENS
LENS
COM
FOCUS
ZOOM
IRIS
PRST
COM
PRST
FOCUS
PRST
PRST
ZOOM
HI
CAM
CAM
5
CAM1
CAM2
DEF
P6
P2
P3
J1
P1
1
CAUTION!
VOLTAGE
PELCO
FAN
PA05-0003-
LENS CONTROL
HTRS
P5
TH1
P4
1
Figure 2. Circuit Board Component Locations
Table B. Video Coaxial Cable Wiring Distances
Cable Type* Maximum Distance
RG59/U 750 ft (229 m)
RG6/U 1,000 ft (305 m)
RG11/U 1,500 ft (457 m)
*Minimum cable requirements:
75 ohms impedance
All-copper center conductor
All-copper braided shield with 95% braid coverage