SafeGuard 20071 Security Camera User Manual


 
26 MARMITEK
8. Advanced system functions
8.1 Setting the delays
You can set a number of delay times via the menu DELAYS:
ENTRY DELAY The time you get to switch off the system after entering your house (factory setting 30 seconds).
EXIT DELAY The time you get before the system is switched on when you leave your house (factory setting 60 seconds).
ANSWER DELAY Delay before the system picks up the phone when dialling in (11.2, factory setting 5 seconds).
DIAL DELAY Delay before the system calls out in case of an alarm (factory setting 30 seconds).
Setting the delays:
1. To access the menu, press the menu or menu button. The display will now read ‘ENTER PIN’.
2. Enter your 4-digit PIN code (factory setting 0000. See 8.3 for changing the PIN code). For every digit entered, a * will appear
on the display.
3. When the PIN code has been entered correctly, the word ‘INSTALL’ will show up on the display.
4. Use the menu buttons / to go to menu item 8. DELAYS. Press OK to select this menu item. You can also go to this menu
item directly by pressing an 8 on the number pad.
5. Select ENTRY DELAY, EXIT DELAY, ANSWER DELAY or DIAL DELAY and press OK.
6. Enter the time required (1-99 seconds). Press OK. Press CLEAR to delete the values entered.
7. Press CLEAR again to quit the menu.
The entry delay only works for the DS90 Door/Window Sensor if set to MAX. MS90 motion detectors will respond instantly.
8.2 Clearing the memory of your security system
You can delete sensors, remote controls, timers or all settings via the menu MEMORY CLEAR.
The PIN code is never erased. This code can only be reset by a Marmitek Authorised Service Center.
1. To access the menu, press the menu or menu button. The display will now read ‘ENTER PIN’.
2. Enter your 4-digit PIN code (factory setting 0000. See 8.3 for changing the PIN code). For every digit entered, a * will appear
on the display.
3. When the PIN code has been entered correctly, the word ‘INSTALL’ will show up on the display.
4. Use the menu buttons / to go to menu item 6. MEMORY CLEAR. Press OK to select this menu item. You can also go to this
menu item directly by pressing a 6 on the number pad.
5. Select CLEAR ALL SENSORS, CLEAR ALL REMOTES, CLEAR ALL TIMERS or MASTER RESET.
6. You are now asked to CONFIRM CLR. Press 1 for Yes or 2 for No.
7. Press CLEAR again to quit the menu.
CLEAR ALL SENSORS emove a registered sensor.
CLEAR ALL REMOTES Remove a registered remote control or SD10 smoke detector.
CLEAR ALL TIMERS Remove all timer settings at once.
MASTER RESET Clear the memory
EXTRA OPTIONS
20071_20070228_UG_SC9000_EN 08-03-2007 10:07 Pagina 26