Samsung SDZ-300 Digital Camera User Manual


 
COLOR CCD CAMERA User’s Manual
17
COLOR CCD CAMERA User’s Manual
16
Connection
Connecting to connection
External Control Connector
Communication Control Connector
Connector
Signal Level I/O
Function
* MD (Motion Detection) Output Signal Level (less than 10mA)
* When using the MD function, the 'GND' should be connected to the frame ground.
The camera can be controlled by using external controllers like a Remote
controller. (RS-485 Communication)
Tele
I
Wide
Far
I
Near
-
O
ZOOM
FOCUS
COM
MD
There is motion
+4.0V~+5.0V
There is no motion
0V
5±0.5sec
COM
-6V~-12V
COM
+6V~+12V
COM
-6V~-12V
COM
+6V~+12V
COM
GND
MD
COM
FOCUS
ZOOM
* Communication Control Connector Pin Description .
* EXT. SYNC
• Contact an authorized technician for inspection.
Notes
3V or 5V
0V
SCC-3000
6-Pin Connection
Cable
Number Name Description
1 GND -
2 EXT.SYNC External ‘SYNC’ Signal
3 GND -
Number Name Description
4TRX + RS-485 Communication
5 TRX - RS-485 Communication
6 Output Power Remote Controller only
* Communication Setting can set the communication setting as shown in the table below.
When you use to connect SCC-100 or SCC-3000, the default sets for SCC-3000
ITEM SCC-100 SCC-3000
MODE Serial Serial
Data Bit 8 bit 8 bit
Bit/Sec 9600bps 9600bps
Parity EVEN NONE
CAM ID NO. 0 1~255
RETURN PACKET ENABLE See the SCC-3000 manual
Min: 500ns
60Hz ± 0.1Hz(NTSC), 50Hz ± 0.1Hz(PAL)
Remote Controller
SCC-100