3-6) ALARM MENU Function setting
•
Function: Allows users to set the ALARM MODE for each camera.
•
Setting method: Move to #6. ALARM MENU by using
œœ
ENTER
√√
SWITCH at SETUP
MENU, and press the ENTER SWITCH to display the OSD as shown in the
figure below. (The figure shows the initial setting status.)
(1) CAM1 to CAM8 item sets whether the alarm sensor connected to the camera is used or not.
(ON: Alarm function setting, OFF: Alarm function canceling)
(2) HOLD TIME item sets time to freeze alarm operation when alarm occuring.
(HOLD TIME to be set: 05SEC ~ 1MIN ~ 30MIN)
(3) ALARM ON/OFF TIME item sets beginning time (ON) and end time (OFF) that monitor
recognizes alarm operation as alarm event.
* Note :Even if CAMERA ALARM is set to ON, alarm operation is not carried at time band except
pre-set ALARM ON/OFF TIME.
(4) BUZZER item sets whether or not buzzer device set in monitor is used at an ALARM or LOSS
occurring.
(ON: Buzzer operation, OFF: NA)
06/01/03 13:14:00
CAM1 ON
CAM2 ON
CAM3 ON
CAM4 ON
CAM5 ON
CAM6 ON
CAM7 ON
CAM8 ON
HOLD TIME 05SEC
ALARM ON TIME 00:00
ALARM OFF TIME 00:00
BUZZER ON
ALARM SETTING