Samsung SPD-3350 Security Camera User Manual


 
SPEED DOME CAMERA User’s Manual
72
SPEED DOME CAMERA User’s Manual
73
Alarm Output
Setting1
1 2 3 4
MD
TRK
Setting2
1 2 3 4
MD
TRK
Timer 1 OFF
Timer 1 OFF
Alarm Setting
Alarm Enable OFF
Alarm Input
Alarm Output
Aux Output
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Status
25.2. Alarm Output
Main Menu/Alarm Setting/Alarm Output
Setting 1,2
:
Enables selecting an Alarm Output method.
- 1, 2, 3, 4, and MD on the menu selection indicate the
alarm input port and motion detection input. Up to 4
alarm inputs can be set for each MD (Motion Detection)
and TRK (Auto Track). 1 alarm output port can be used for
more than 2 alarm inputs along with ones for MD and
TRK.
Timer
:
Enables selecting an Alarm Output method.
- On : Retains an alarm output for a set duration from a
minimum of 1 second to a maximum of 60 hours
upon the alarm occurrence.
- Momentary : Retains an alarm output only until the alarm
is canceled.
The TRK function becomes activated only if the Zone mode
under Zone Settings under Auto Track 2 is set to Alarm.
The Alarm Output is equipped with a relay circuit. The
operation of the alarm output port is as shown in the
diagram below.
•ConnectingthepowerconnectorandGNDincorrectlytotheNC/NOandCOMportsmay
cause a short circuit and fire, damaging the camera.
•Themaximumpowercapacityofthebuilt-inrelayis30VDC/2A,125VAC/0.5A,and
250VAC/0.25A. Operating the camera beyond the capacity may decrease the camera’s
lifespan and damage it.
Notes
NO NO
NC NC
COM COM
Alarm Out OFF Alarm Out ON
Alarm Setting
Alarm Enable OFF
Alarm Input
Alarm Output
Aux Output
AUX Output
On/Off OFF
Time 00 SEC
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Status
25.3. Aux Output
Main Menu/Alarm Setting/Aux Output
•ConnectingthepowerconnectorandGNDincorrectlytotheAuxterminal’sNOandCOM
ports may cause a short circuit and fire, damaging the camera.
•Themaximumpowercapacityofthebuilt-inrelayis30VDC/2A,125VAC/0.5A,and
250VAC/0.25A. Operating the camera beyond the capacity may decrease the camera’s
lifespan and damage it.
Notes
AUX Output menu is to operate the camera’s peripheral
devices such as lamps and sirens through the controller and
switches as well as through network communications.
On/Off
:
- Cancels or activates the Aux function.
Time
:
Enables setting up a duration for the Aux output when the
Aux command is transmitted from the controller. A
duration can be selected from a minimum of 1 second to a
maximum of 60 minutes.
NO
COM
AUX Off
NO
COM
AUX On
Functional Description Functional Description