Sanyo VPC-SX560E Digital Camera User Manual


 
19
4. AWB adjustment value will appear on the screen.
5. Click the OK.
8. Lens Adjustment
Preparation:
POWER switch: ON
Adjustment condition:
More than A3 size siemens star chart
Fluorescent light illumination with no flicker
Illumination above the subject should be 400 lux 10 %.
Adjustment method:
1. Set the siemens star chart 95 cm 3 cm so that it be-
comes center of the screen.
2. Double-click on the DscCalDi126.
3. Click the Focus, and click the Yes.
4. Lens adjustment value will appear on the screen.
5. Click the OK.
9. CCD Defect Detect Adjustment
Preparation:
POWER switch: ON (Set the camera mode.)
Adjustment method:
1. Double-click on the DscCalDi126.
2. Select CCD Defect Detection on the LCD Test , and click
the Yes.
3. After the adjustment is completed, OK will display.
4. Click the OK.
10. LCD Panel Adjustment
[CA3 board (Side A)]
10-1. LCD H AFC Adjustment
Preparation:
POWER switch: ON
Adjusting method:
1. Double-click on the DscCalDi126.
2. Select 0 on the LCD H AFC.
3. Apply the trigger at CL173, and adjust VR171 so that the
time A from the point where the pulse at CL170 rises until
the position where the video signal at CL173 starts in 0.82
0.1 µsec (for VPC-SX560EX and VPC-SX560E) or 1.5
0.1 µsec (for VPC-SX560).
Serial cable
Camera
Approx.
95 cm 3 cm
Siemens
star chart
enlargement
A
CL170
CL173
A
CL170
CL173
CL171
CL173
CL172
VR171
CL170