Sony CCU-M5AP Security Camera User Manual


 
Location and Function of Parts
12
FUNCTION buttons
Use these buttons to move the arrow cursor up and
down to specific menu items displayed on the monitor.
DATA buttons
Use these buttons to change the setting of displayed
menu items that have been selected by the
FUNCTION buttons.
RESET button
Press this button to reset menu items that have been
selected by the FUNCTION buttons to their factory
settings.
qg PHASE adjustment section
H (horizontal phase adjustment) control
Using a screwdriver, rotate this control to adjust the
horizontal phase difference between the external sync
signal and the signal output from this unit.
SC (subcarrier phase adjustment) switch
Set to adjust the subcarrier phase difference between
the external sync signal and the signal output from this
unit.
SC (subcarrier phase adjustment) control
After setting the SC switch to the appropriate position,
rotate this control using a screwdriver to make fine
adjustment of the subcarrier phase difference.
qh SHUTTER adjustment section
SHUTTER switch
Use to activate or deactivate the electronic shutter.
ON: Activates the electronic shutter.
OFF: Deactivates the electronic shutter.
SHUTTER selector
Use to select the speed of electronic shutter.
SHUTTER selector position Shutter speed
1 1/100 sec. (NTSC), 1/60
sec. (PAL)
2 1/250 sec.
3 1/500 sec.
4 1/1000 sec.
5 1/2000 sec.
C.SCAN Activates the Clear Scan
function.
C.SCAN (Clear Scan) buttons
When the SHUTTER switch is set to C.SCAN, press
these buttons repeatedly to select the Clear Scan
frequency. If the SHUTTER switch is set to ON, the
setting is stored in memory and retained even the
power of this unit is turned off.
Display
Displays the selected shutter speed or Clear Scan
frequency. “OFF” is displayed when the SHUTTER
switch is set to OFF.
qj MODE switch
Use to select the video signal to be output from this
unit.
CAMERA: Image being shot via video camera
BARS: Color bars generated by this unit
PHASE
180˚
0˚
SC
H
H control
SC switch
SC control
SHUTTER
ON
OFF
Hz
C.SCAN
1
2
3
4
5
SHUTTER switch
SHUTTER selector C.SCAN buttons
Display