Toshiba IK-53V Digital Camera User Manual


 
12
Pulse Width Trigger SYNC-NON RESET Picture Output Timing
(At Time of One-shot or Continuous External VD/Continuous External HD Input)
*1: Externally input signal
*2: Exposure time = Trigger pulse width + 6 µs
(Valid trigger pulse width is 2 µs or greater for external trigger shutter operation.)
*3: Video is output at the falling edge of the internal VD following completion of the exposure
period.
The video and the VIDEO INDEX have a paired relationship.
NOTE
When the next trigger is input before completion of the output of the video corresponding to
the trigger, there will be an effect on the video.
About 1 µs
Exposure period*
2
Partial scanning OFF)
Partial scanning ON)
The internal VD falling edge is within the exposure
period and thus video is not output.
*
3
*
1
*
1
About 7 µs
About
Negative polarity mode
Positive polarity mode
Exposure period*
2
Trigger*
1
1 Pulse Trigger SYNC-NON RESET Picture Output Timing (at Time of Internal Sync)
About 1 µs
Exposure period
*
2
Video output
525H (Partial scanning OFF)
175H (Partial scanning ON)
VIDEO INDEX
VD OUT*
3
Trigger*
1
Negative polarity mode
Positive polarity mode
Exposure period
*
2
*1: Externally input signal
*2: Exposure time is determined by the setting of the MODE SELECT switch. Refer to page 10.
As long as there is no external sync input, the internal VD will be output when the rear
panel HD/VD signal input/output switch is set to the INT side.
*3: Video is output at the falling edge of the internal VD following completion of the exposure
period.
The video and the VIDEO INDEX have a paired relationship.
NOTE
When the next trigger is input before completion of the output of the video corresponding to
the trigger, there will be an effect on the video.