28
(3. 2) Pulse Width Trigger SYNC-NON RESET Picture Output Timing (at Time of Internal Sync)
*1: Externally input signal
*2: Exposure time = Trigger pulse width + 6 µs
(Valid trigger pulse width is 2 µs or greater for external trigger shutter operation.)
*3: As long as there is no external sync input, the internal VD will be output when SJ01 is set to HD/VD output
position.
*4: Video is output at the falling edge of the internal VD following completion of the exposure period.
The video and the VIDEO INDEX have a paired relationship.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig-
ger, there will be an effect on the video.
About 1 µs
Exposure period*
2
Video output
796H (Partial scanning OFF)
387H (Partial scanning 60fps)
258H (Partial scanning 90fps)
VIDEO INDEX
VD OUT*
3
Trigger*
1
Exposure period*
2
Negative polarity mode
Positive polarity mode
About 7 µs