( 4 ) PW SR (Pulse width trigger SYNC-RESET)
The trigger input to the CC1 of the DIGITAL terminal develops 1 frame images.
(4. 1) 1 Pulse Width Trigger SYNC-RESET Picture Output Timing
*1: Externally input signal
*2: Exposure time = Trigger pulse width + 6 µs
(Valid trigger pulse width is 2 µs or greater for external trigger shutter operation.)
*3: VD is generated after 0 to 2H following the completion of the exposure period and the video is synchro-
nized to this and output.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig-
ger, there will be an effect on the video.
About 1 µs
About 7 µs
Exposure completion
0 to 2H
Tr igger*
1
Negative polarity mode
Positive polarity mode
Exposure period*
2
(Internal VD)
*
3
RGB data
(video interval image)
FVAL
LVAL,
DVAL
58H (
Partial scanning OFF
)
40H (
Partial scanning
25fps)
56H (
Partial scanning
30fps)
66H (
Partial scanning
35fps)
78H (
Partial scanning
40fps)
80H (
Partial scanning
45fps)
86H (
Partial scanning
50fps)