The table shows the strobe index by the increment step through strobe delay time and strobe duration time.
Increment Step is different according to strobe index.
Strobe Delay/Duration Table
Strobe Index(Y) Increment Step
Strobe Delay Time : T
Delay Time Duration Time Range
0
0us
N.A
1 1us N.A
2 2us 2us
3~250 1us T=Y us T=Y us 3us~250us
251~489
250us
T=(Y-250)*250us+250us
T=(Y-250)*250us+250us
500us~60ms
Strobe Delay/Duration Index Strobe Delay Time Strobe Duration Time
0 0us N.A
1 1us N.A
2 2us 2us
10 10us 10us
100 100us 100us
250 250us 250us
253 1ms 1ms
257 2ms 2ms
269 5ms 5ms
289 10ms 10ms
329 20ms 20ms
449 50ms 50ms
489 60ms 60ms