delay 1~999 20 6/6 Delay in seconds before detecting the
next event.
trigger boot,
di,
motion,
seq,
recnotify,
tampering,
visignal,
vi
boot 6/6 Indicate the trigger condition:
“boot” = System boot
“di”= Digital input
“motion” = Video motion detection
“seq” = Periodic condition
“visignal” = Video input signal loss.
“recnotify” = Recording notification.
“tampering” = Tamper detection.
“vi”= Virtual input (Manual trigger)
triggerstatus String[40] trigger 6/6 The status for event trigger
di <integer> 1 6/6 Indicate the source id of di trigger.
This field is required when trigger
condition is “di”.
One bit represents one digital input.
The LSB indicates DI 0.
mdwin <integer> 0 6/6 Indicate the source window id of
motion detection.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set mdwin as 5.
mdwin0 <integer> 0 6/6 Similar to mdwin. The parameter
takes effect when profile 1 of motion
detection is enabled.
vi <integer> 0 6/6 Indicate the source id of vi trigger.
This field is required when trigger
condition is “vi”.
One bit represents one digital input.
The LSB indicates VI 0.
inter 1~999 1 6/6 Interval of snapshots in minutes.
This field is used when trigger
condition is “seq”.