Vivotek VS8102 Security Camera User Manual


 
VIVOTEK
User's Manual - 131
PARAMETER VALUE DESCRIPTION
com 1 ~ <max. com port
number>
The target COM/RS485 port number.
data <hex decimal data>[,
<hex decimal data>]
The <hex decimal data> is a series of digits from 0 ~ 9, A ~ F. Each
comma separates the commands by 200 milliseconds.
flush yes,no yes: Receive data buffer of the COM port will be cleared before read.
no: Do not clear the receive data buffer.
wait 1 ~ 65535 Wait time in milliseconds before read data.
read 1 ~ 128 The data length in bytes to read. The read data will be in the return page.
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length: <system information length>\r\n
\r\n
<hex decimal data>\r\n
Where hexadecimal data is digits from 0 ~ 9, A ~ F.
Storage managements (capability.storage.dbenabled=1)
Note: This request requires administrator privileges.
Method: GET and POST
Syntax:
http://<servername>/cgi-bin/admin/lsctrl.cgi?cmd=<cmd_type>[&<parameter>=<value>…]
The commands usage and their input arguments are as follows.
PARAMETER VALUE DESCRIPTION
cmd_type <string> Required. Command to be executed, including search, insert, delete, update, and
queryStatus.
Command: search
PARAMETER VALUE DESCRIPTION
label <integer
primary key>
Optional.
T
he integer primary key column will automatically be assigned a
unique integer.
triggerType <text> Optional. Indicate the event trigger type. Please embrace your input value
with single quotes.