3Com 09-0704-001 Security Camera User Manual


 
3.5. AccessBuilder Configuration 3-5
3.5.
AccessBuilder
Configuration
In order for the AccessBuilder to work with the Name Server client, the
following parameters in the AccessBuilder (under the admin directory) must
be set to work properly:
1 SecurityServerType
Set this parameter to AB (AccessBuilder Name Server).
2 SecurityPasswd
This parameter has to be the same as the ‘-p password’ command option to
’dbserver’. The default value is 3com.
3 ScrtyClntIpAddr
This parameter is set to the IP address of the UNIX workstation which runs
the Name Server.
4 ScrtyClntUdpPort
This parameter has to be set to the same UDP port number as the ‘crsecacc’
entry of the /etc/services file. The default value is 888.
5 Date
This parameter is set to the current date.
6 Time
This parameter is set to the current time.
These steps may be performed using the Security Clients Parameters dialog
box in Transcend AccessBuilder Manager.