- 58 -
Appendix
A. Troubleshooting
Status LED
After powering up, the Network Camera performs a self-diagnostic to detect any
hardware defects. The following table lists the LED patterns in general. In case of any
fatal error, the LED will blink in a pattern other than those below.
Condition LED color
During self-diagnostic after power on Blink in interchanged green and red
Ethernet signal is lost Red LED is off till Ethernet is detected
Before network is setup Steady green till IP address is confirmed
After network is setup Blink green every second
Any hardware failure Other patterns
Reset and Restore
At the left side of the camera there is a button
hidden in the pinhole as shown in the picture.
It is used to reset the system or restore the
factory default settings. Sometimes resetting
the system sets the system back to normal
state. If the system problems remain after
reset, restore the factory settings and install
again.
RESET: Poke the wrench to click on the button.
RESTORE: 1. Poke the wrench to press on the
button continuously.
2. Wait for self-diagnostic to run twice.
3. Withdraw the wrench as soon as the second
self-diagnostic starts.
Restoring the factory defaults
will erase any previous settings.
Reset or restore the system after
power on.