Bosch Appliances NWC-0700 Digital Camera User Manual


 
40 en | Software MegaPixel IP Cameras
F.01U.064.422 | V 1.0 | 2007.03 User Manual Bosch Security Systems
c. Check "Motion camera" if motion-triggered recording
is used with this camera.
d. Enter the port number as defined in the HTTP com-
mand string.
e. For “On command” enter: ismotion
f. For Off command enter: nomotion
g. Click OK to save the entered configuration.
All remaining DiBos8 recording settings are standard.
4.3.3 HTTP command string parameters
The generic HTTP command string has the following format:
http://<ip_address>/
image?res=<resolution_value>&x0=<x0_value>&y0=
<y0_value>&x1=<x1_value>&y1=<y1_value>&qualty=
<quality_value>&doublescan=<doublescan_value> [&mdn=
<port_no>]
Table 3.1 describes the parameters.
The requested image can have a smaller size (electronic zoom
function) than the camera sensor size. The image size is defined
by the x0, y0, x1, and y1 coordinates on the sensor. For the
NWC-0700 and NWC-0800, the coordinates are defined in pix-
els. The NWC-0900 has two sensors of differing resolution. Set
the x and y coordinates for the 3.1 MegaPixel sensor.
x0 and y0
These two parameters define the left-hand, top-corner point of
the requested image. For the NWC-0700 and NWC-0800 the val-
ues are in pixels.
x1 and y1
These two parameters define the right-hand, bottom-corner
point of the requested image on the imaging device. For the
NWC-0700 and NWC-0800 the values are in pixels.