Canon DXC-D35K/D35PK Digital Camera User Manual


 
Chapter 2 Fitting and Connections
Chapter 2 Fitting and Connections 39
Connecting a Number of Cameras (Without Using a Camera Control
Unit)
When using two or more synchronized cameras
without a camera control unit, connect an external sync
signal to the GEN LOCK IN connector on the camera
adaptor (CA-537/537P etc.), supplying a VBS or BS
signal. The camera will then operate synchronized to
this signal.
You can adjust the synchronization using the basic
menus. (See page 59.)
VTR/CCU/CMA
VIDEO OUT VIDEO OUT
GEN LOCK IN
VIDEO OUT
GEN LOCK IN
VIDEO OUT
GEN LOCK IN
Example 1: Camera 2 synchronized to the signal from camera 1
CA-537/537P
Camera 1
DXC-D35/D35P/
D35WS/D35WSP
CCZ-A Camera Cable
BNC cable
Portable VTR
To camera
connector
To video input
connector
CA-537/537P
Camera 2
DXC-D35/D35P/
D35WS/D35WSP
Example 2: Cameras 1 and 2 synchronized to the signal from a special effects unit or similar
Special effects
unit or similar
Video input connector
BNC cable
Sync signal output
connector
CA-537/537P
DXC-D35/D35P/D35WS/
D35WSP
BNC cable
Video input connector BNC cable
CA-537/537P
Camera 2
Camera 1
DXC-D35/D35P/D35WS/
D35WSP
Sync signal output
connector
BNC cable
BNC cable