Canon PC960 Camcorder User Manual


 
CHAPTER 6 FIXING SYSTEM
COPYRIGHT
©
1999 CANON INC. CANON PC800s/900s REV.0 AUG. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
6-1
Table 6-101
Item
Fixing method
Fixing drive
Fixing heater
Fixing temperature
detection
Cleaner
Protective functions
Error code
Description
SURF
Main Motor (M1)
Flat heater
Thermistor (TH1)
Cleaning roller
The following are used to detect and protect against
an error; upon detection, power to the fixing heater
will be cut:
• Thermistor (TH1)
• Thermal fuse (FU2; activating at 228°C)
E000 The fixing temperature fails to increase.
E001 The thermistor has detected overheating.
E002 Fault in fixing power control.
E003 The fixing temperature has dropped
abnormally.
I. OPERATIONS
A. Outline
The major functions of the fixing unit are as follows: