VII. SELF DIAGNOSIS
The microprocessor on the machine’s DC controller PCB is equipped with a self diagnostic
mechanism that checks the condition of the machine (particularly, sensors) and indicates an error
code in the count/ratio indicator on the control panel upon detection of a fault.
In the case of ‘E001’, ‘E0’ and ‘01’ are flashed alternately.
Code Cause Description
‘E000’, ‘E001’, ‘E002’, or ‘E003’ has
occurred.
The thermistor (TH1) is faulty.
The fixing heater (H1) is faulty.
The thermal fuse (FU2) has blown.
The DC controller PCB is faulty.
The composite power supply PCB is
faulty.
The thermistor (TH1) is faulty.
The DC controller PCB is faulty.
The composite power supply PCB is
faulty.
The thermistor (TH1) is faulty.
The fixing heater (H1) is faulty.
The thermal fuse (FU2) has blown.
The DC controller PCB is faulty.
The composite power supply PCB is
faulty.
The thermistor (TH1) is faulty.
The fixing heater (H1) is faulty.
The thermal fuse (FU2) has blown.
The DC controller PCB is faulty.
The composite power supply PCB is
faulty.
The power switch is turned off and then
on immediately after an error (‘E000’,
‘E001’, ‘E002’, ‘E003’) has occurred.
The temperature detected by the
thermistor (TH1) does not reach 65°C
1.5 sec after the Copy Start key has
been pressed.
The temperature detected by the
thermistor (TH1) does not reach 150°C
4 sec after the Copy Start key has been
pressed.
The temperature detected by the
thermistor (TH1) exceeds 230°C.
The temperature detected by the
thermistor (TH1) exceeds by 30°C or
more.
The temperature detected by the
thermistor (TH1) registers an increase
of 100°C or more within 1 sec.
The temperature detected by the
thermistor (TH1) registers an increase
of 40°C or more after it has reached
100°C during standby.
E0 detection signal (E0_DT) is de-
tected twice or more in succession.
The temperature detected by the
thermistor (TH1) has exeeded 150°C
during copy operation and maximum
power is applied for 10 to 14 sec
thereafter.
The temperature detected by the
thermistor (TH1) drops to and remains
150°C or lower after it has reached
160°C.