- Click the “PAN/TILT & REMOTE” button in the PAN/TILT menu shown in
Fig.4-5, then the vendor lists will show up. Select “PELCO” on the vendor lists
by clicking the mouse and then the protocol “PELCO D” will display.
- Click the “BAUD RATE” button in the PAN/TILT menu and choose 2400bps
among 1200bps, 2400bps, 4800bps, 9600bps, 19200bps, 38400bps, 57600bps and
115200bps on the Baud Rate pop-up window by clicking the mouse.
- Do not change the settings for Data Bits, Stop Bits and Parity Bits.
Connect the RED and BLUE colored wire of the Data Cable (Twisted Pair Cable) to the
“+” and “-“ terminals on the rear of the camera and the DVR system as shown in Fig5-
1. Refer to the instruction manual of DVR system relevant to the location of “+” and
“-“ terminals for RS485.
To connect the bared copper wire on the end of the RED and BLUE colored wire, push
the terminal with “-“driver (2mm) until inserting it into the round hole as shown in
Fig.5-2.
5. INSTALLATION
Tips for Quick Setup on the DVR system:
- Enter the same ID as the zoom camera has.
e.g.1: if the ID of the zoom camera is “000”, enter “0” in the PTZ ID box.
e.g.2: if the ID of the zoom camera is “007”, enter “7” in the PTZ ID box.
- The protocol should be “PELCO D”.
- Choose the Baud Rate (communication speed) 2400bps on the pop-up
menu.