Faber M1024 Security Camera User Manual


 
Genie Monochrome Series-GigE Vision Camera Operational Reference 67
Genie Power-up Configuration
On power up the Genie camera initializes to a factory default state which sets the camera with neutral parameters
and in free run mode. The default state ensures that the camera is ready for acquisition. Genie also provides storage
for one user-defined state. This user state allows quick camera configuration for a known repeatable imaging
system. The following table describes the camera parameters stored in the user state. See "
Power-up Configuration"
on page 32 for information on saving the user state with CamExpert.
Parameter Description
ROI Region of interest used to crop the image
Pixel Format Defines the pixel format (MONO8)
Frame Rate Defines the frame rate for free run mode.
Exposure mode Defines the exposure mode (Programmable or Pulse Controlled)
Exposure duration Defines the exposure duration for Programmable mode
Exposure synchronization Synchronous or Reset synchronization mode
Gain Defines the sensor analog Gain factor.
Black Level Defines the sensor analog Black level factor.
Binning Horizontal and vertical binning factor
Flip Horizontal flip: Off or On
Image source Defines the image source as the sensor or one of the stored image patterns.
Trigger enable Free-running or triggered
Trigger source Selects the trigger input (input pin or software)
Trigger delay Defines the delay from input trigger to exposure start.
GPI settings Defines the operational mode of the general input pins.
GPO settings Defines the operational mode of the general output pins
LUT Lookup Table function On or Off plus the LUT data.
Flat Field Correction FFC function On or Off plus the offset/gain data.