FujiFilm XT174.5BRM-K14 Camera Lens User Manual


 
– 3 –RM-K1
ADJUSTMENT OF FLANGE FOCAL LENGTH
e ange focal length is the distance from the ange (mounting surface) of a lens to the focal plane.
If the focal plane of the lens does not coincide with the image plane of the camera, the object will be out of focus
during a zoom operation. To prevent this from happening, the adjustment of the ange focal length is required. Make
sure to carry out the adjustment when installing the lens to a camera for the rst time or installing it to another
camera.
CONDITIONS OF OBJECT AND DIAPHRAGM
1. Object: cut “Siemens Star” o at the end of this manual and use it as an object
2.
Distance of Object: about 3 meters
3.
Diaphragm: open or as near to open as possible
Note. e depth of eld decreases by opening the aperture of the lens, and it becomes possible to focus on an object
more precisely. To precisely adjust the ange focal length, carefully adjust the focus as much as possible.
Flange
Focal Plane
Flange Focal Length