JAI TS(C)-4032EN Digital Camera User Manual


 
EN Camera Series
44 Camera Features
Table 6 EN Exposure Times
TS(C)-2030EN/TS(C)-2076EN
(55.0 μs x H + 28.7 μs)
TS(C)-1327EN
(633 μs x H + 5.1 μs)
TS(C)-4032EN
(24 μs x H)
Shutter
Dial
Exposure
Time
(H)
Exposure
Time (
μs)
Exposure
Time
(H)
Exposure
Time (μs)
Exposure
Time
(H)
Exposure
Time (μs)
1 1 83.7 1/2
36.8
1
24
2 2 138.7 1
68.4
1.5
36
3 3 193.7 2
131.7
2
48
4 4 248.7 4
258.3
3
72
5 6 358.7 6
384.9
4
96
6 8 468.7 8
511.5
6
144
7 9 523.7 9
574.8
8
192
8 10 578.7 10
638.1
12
288
9 11 633.7 11
701.4
16
384
A
13 743.7 13
828.0
21
504
B 15 853.7 15
954.6
26
624
C 17 963.7 17
1081.2
36
864
D 18 1,018.7 18
1144.5
44
1056
E 126 6,958.7 126
7980.9
64
1536
F 262 14,438.7 262
16,589.7
84
2016
0 525 28,903.7 1040
65,837.1
1365 32,760
When the EN camera is controlled by light sensor, user can monitor the shutter value in EN setup
software by accessing "Camera Shutter" status register (Address = 233). Note that this Shutter value
is dial number and not actual exposure time, (left side of the table above).
User needs to set appropriate "ADR Shutter Max" and "ADR Shutter Min" config registers (Address =53
and 58 respectively) to limit exposure time. In daytime, "ADR Shutter Min" limits the shortest
exposure time (or faster shutter speed). In night time, "ADR Shutter Max" limits the longest exposure
time (or slowest shutter speed). The factory default settings of "ADR Shutter Min" and "ADR Shutter
Max" are as follows: Factory Default Settings of the ADR Shutter Min. and Max.
Table 7 Factory Default Settings of the ADR Shutter Min. and Max.
TS(C)-2030EN/TS-2076EN
TS(C)-1327EN
TS(C)-4032EN
BW Color
BW
Color
BW Color
ADR shutter Min Dial=1 (1H) Dial=3 (3H)
Dial=1 (1/2H)
Dial=3 (2H)
Dial=1 (1H) Dial=5 (4H)
ADR Shutter Max Dial=7 (9H) Dial=11 (15H)
Dial=6 (8H)
Dial=11 (15H)
Dial=10 (21H) Dial=12 (36H)