Example When setting Sunday filter of Alarm No. 1
/api/param?application.event(1).filter(sunday).status=on
Example of Response
application.event(1).filter(sunday).status&202 Accepted(application.event(1).status=restart)
Interpretation Set filter setting of the alarm action for the specified alarm number. Up to 5 alarm actions can be
specified, periodic FTP is assigned to event No.6, and pre/post FTP assigned to No.7. Therefore the number of
event(number) can be set between the range of 1 to 7. Note that alarm numbers are different from the alarm input
pin numbers.
Specify sunday, monday, tuesday, wednesday, thursday, friday or saturday for WeekOfDay.
Specify on to enable the filter, off to disable the filter.
The changes to filter of alarm action is saved by /api/param?application.event(Number).status=restart.
Allowed users admin, operator
Getting Alarm Filter Time
Format /api/param?application.event(Number).filter(WeekOfDay).time
Example When Getting Time of Sunday filter of Alarm No. 1
/api/param?application.event(1).filter(sunday).time
Example of Response application.event(1).filter(sunday).time=000000-240000&200 OK
Interpretation Acquire filter time of the alarm action for the specified alarm number. Up to 5 alarm actions can be
specified, periodic FTP is assigned to event No.6, and pre/post FTP assigned to No.7. Therefore the number of
event(number) can be set between the range of 1 to 7. Note that alarm numbers are different from the alarm input
pin numbers.
Specify sunday, monday, tuesday, wednesday, thursday, friday or saturday for WeekOfDay. Start time and end
time is returned in the format like hhmmss-hhmmss. Start time can be from 000000 to 235959. End time can be
from 000001 to 240000.
Allowed users admin, operator
Setting Alarm Filter Time
Format /api/param?application.event(Number).filter(WeekOfDay).time=data
Example When setting Sunday filter time of Alarm No. 1
/api/param?application.event(1).filter(sunday).time=010200-040500
Example of Response
application.event(1).filter(sunday).time&202 Accepted(application.event(1).status=restart)
Interpretation Set filter time of the alarm action for the specified alarm number. Up to 5 alarm actions can be
specified, periodic FTP is assigned to event No.6, and pre/post FTP assigned to No.7. Therefore the number of
event(number) can be set between the range of 1 to 7. Note that alarm numbers are different from the alarm input