JVC 237 Security Camera User Manual


 
To set recording quality to Mid
/api/param?encode(3).type=h264high
/api/param?encode(3).framesize=1280x720
/api/param?encode(3).framerate=5
/api/param?encode(3).bitrate=768000
/api/param?encode(3).cbr_mode=cbr
/api/param?encode(3).iframeinterval=5
To set recording quality to Low
/api/param?encode(3).type=h264high
/api/param?encode(3).framesize=640x360
/api/param?encode(3).framerate=5
/api/param?encode(3).bitrate=128000
/api/param?encode(3).cbr_mode=cbr
/api/param?encode(3).iframeinterval=5
Allowed users admin, operator
14. JVC API for Digital PTZ
The APIs below are related to digital PTZ control. These are equivalent to the features on the PTZ page of the
WEB setting page. Refer to the instruction manual for details on the PTZ page.
Basic authentication is required for JVC API explained in Section 7 or later. This section provides general
explanation of those APIs. The API is valid when the resolution is 640x360 or 640x480.
(1) Settings for PTZ Control
Getting Auto Return Mode
Format /api/param?camera.motion.auto_return.mode
Example of response camera.motion.auto_return.mode=home&200 OK
Interpretation Acquire Auto Return mode. "home" or "auto_patrol(0)" will be returned.
Allowed users admin, operator, user
Setting Auto Return Mode
Format /api/param?camera.motion.auto_return.mode=data
Example of Response camera.motion.auto_return.mode&202 Accepted(camera.status=save)
Interpretation Change Auto Return mode. Specify "home" or "auto_patrol(0)". The change is saved by the API,
camera.status=save. If the change is not saved, the setting is restored by reboot.