6
4. Object and Liquid Entry
Never push objects of any kind into this product through
openings as they may touch dangerous voltage points or
short-out parts that could result in a fire or electric
shock. Never spill liquid of any kind on the product.
5. Attachments
Do not use attachments not recommended by the manu-
facturer of this product as they may cause hazards.
6. Cleaning
Unplug this product from the wall outlet before cleaning.
Do not use liquid cleaners or aerosol cleaners. Use a
damp cloth for cleaning.
7. Sterilization
Before using the endoscope, always be sure to sterilize
the laparoscope video adapter, the HD camera head,
and the camera cable.
8. Heat
The product should be situated away from heat sources
such as radiators, heat registers, stoves, or other
products (including amplifiers) that produce heat.
SERVICING
1. Servicing
If your product is not operating correctly or exhibits a
marked change in performance and you are unable to
restore normal operation by following the detailed
procedure in its operating instructions, do not attempt to
service it yourself as opening or removing covers may
expose you to dangerous voltage or other hazards.
Refer all servicing to qualified service personnel.
2. Damage Requiring Service
Unplug this product from the wall outlet and refer
servicing to qualified service personnel under the
following conditions:
a. When the power supply cord or plug is damaged.
b. If liquid has been spilled, or objects have fallen into
the product.
c. If the product has been exposed to rain or water.
d. If the product does not operate normally by following
the operating instructions. Adjust only those controls
that are covered by the operating instructions as an
improper adjustment of other controls may result in
damage and will often require extensive work by a
qualified technician to restore the product to its
normal operation.
e. If the product has been dropped or damaged in any
way.
f. When the product exhibits a distinct change in
performance—this indicates a need for service.
3. Replacement Parts
When replacement parts are required, be sure the
service technician has used replacement parts specified
by the manufacturer or have the same characteristics as
the original part. Unauthorized substitutions may result
in fire, electric shock or other hazards.
4. Safety Check
Upon completion of any service or repairs to this prod-
uct, ask the service technician to perform safety checks
to determine that the product is in safe operating condi-
tion.
5. Operational Life of the Product
Regular maintenance and inspection is essential for
ensuring safe and long-lasting operation of this product.
Inspect and maintain the product before and after use,
and also have regular maintenance performed by a
specialist.
STERILIZATION:
The camera head with camera cable and video
adapter can be sterilized with ethylene oxide (EO)
and Sterad (50, 100, 100S, 500) supplied by Johnson
& Johnson Medical Inc.
Ethylene oxide
Desorbtion time for ethylene oxide after using aerator:
more than 18 hours
Desorbtion time is based on the following sterilization
parameters:
Ethylene oxide gas : Ethylene oxide 20% and CO2
80%
Temperature : 40˚ to 60˚C
Humidity : 40 to 60% RH
Ethylene oxide density : 500 to 600 mg/l
Desorbtion method : Aeration
Aerator : 50˚C and more than 18 hours
(In room temperature it is
required more than 48 H)
Note: Deterioration of camera cable
Due to ethylene oxide, rubber part of camera
cable may cause deterioration.
Depending on the frequency of use, however at
least once a year, an expert must check the
device.
Sterad (H2 O2 plasma)
In the case of using Sterad, please follow the instruc-
tion of the manufacturer. Because of using Sterad
many times, some cosmetic changes can be ob-
served. However, the functions of HD camera system
are not affected by those.