JVC KY-F70 Digital Camera User Manual


 
E24
@@@@@@
Setting the dip switches
The type of PC monitor to use and the ID during SCSI connection are set using the dip switches.
Monitor settings
Dip switch no. 3 is set depending on whether the PC monitor being used is a VGA monitor or a
SXGA monitor.
<
Default setting: OFF
>
VGA output terminal
Set when directly connecting a VGA monitor to the MONITOR ter-
minal on the rear of the main unit.
SXGA output setting
Set for systems using a SXGA monitor.
The signal from the MONITOR terminal on the rear of the main unit
is inputted through the analog input compatible video capture board.
( Page 65 Compatible systems 2)
SCSI ID settings
Sid switches 1 and 2 are set depending on the used system to set the SCSI ID.
<
Default ID: 7
>
Set when connecting a printer or MO drive directly to the main unit.
When making this setting, the main unit will become the host (ini-
tiator).
Set when exporting images to a PC.
Make sure that the ID numbers of the connecting devices are not
the same.
When making this setting, the PC will become the host (initiator)
and the main unit will become the target.
( Page 64 Connecting to a PC)
MEMO
Turn the power off before setting the dip switches. Setting
the switches with the power on will not change the set-
tings.
3. Settings and adjustments for recording
SEE INSTRUCTION MANUAL
POWER
DC IN
REMOTE
MONITOR
LENS
FREEZE
PLAY
SETDOWN
AW/SELSEND
SCSI
UPMENU
MODE
REC
ON1 23 4
ON 1 2 3 4
ON 1 2 3 4
ON 1 2 3 4
ON 1 2 3 4
ON 1 2 3 4
ON 1 2 3 4
ID=7
ID=6
ID=5
ID=4
Dip switches
Set to OFF
Set to ON