JVC KY-F70 Digital Camera User Manual


 
E61
Menu item
SPEED
SENSITIVITY
LEVEL
ALC MAX
Default value
STEP
STEP:
ISO100
V.SENS:
ISO100
ISO400
Function/variable range
MEMO
In areas which the power supply frequency is 50Hz, set-
ting the unit to 1/100 can reduce flickering when record-
ing under florescent lighting.
There may be shortage of light when increasing the shut-
ter speed. In this case, adjust the iris or sensitivity. Spe-
cial attention is required for the picture quality when rais-
ing the sensitivity since images may become distorted.
Used to set the sensitivity mode.
STEP: the sensitivity can be changed using the LEVEL
submenu item.
ALS: the sensitivity si automatically changed by the
brightness. Maximum sensitivity is set in the next
ALC MAX menu item.
V.SENS: the sensitivity can be set in detail using the
LEVEL submenu item.
The sensitivity can be changed when the sensitivity mode
is set to STEP or V.SENS.
[STEP variable range: ISO100, ISO200, ISO400]
[V.SENS variable range: ISO100 ~ ISO400]
This can be set when the sensitivity mode is set to ALC.
Used to set the maximum sensitivity of ALC, which auto-
matically switches the sensitivity depending on the bright-
ness.
[Variable range: ISO200, ISO400]