JVC TK-C1480 Digital Camera User Manual


 
E-20
CONNECTION/INSTALLATION
Lens adjustment
ALC
LEVEL
Av Pk
L H
Connect the camera according to the connection method, turn it on, display an image on the
monitor, and check the image. The camera has been factory-adjusted to the best position, but
it may need to be adjusted according to the object conditions or combination of lenses. If the
image is unnatural, adjust it as follows: (Also read the instruction manual of the lens.)
• LEVEL adjustment
Monitor screen
LEVEL turning direction
Too bright Counterclockwise (Toward L)
Too dark Clockwise (Toward H)
MEMO
If the sensitivity adjustment LEVEL is
turned excessively to L, the sensitivity in-
creases because of the AGC function of
the camera, and the image looks grainy.
If the video iris lens is set to too low a level,
malfunction such as the hunting phenom-
enon, in which the iris opens or closes
unintentionally, may occur.
In such a case, first set LEVEL potentiom-
eter on the lens to the H (iris open) posi-
tion then adjust it to the optimum level.
LEVEL
adjustment
ALC adjustment
(Does not operate.)
MEMO
Note that the lens cannot make ALC adjust-
ments. Make ALC adjustments using the item
AVERAGE: PEAK on the menu.
( Page 26)