Turn OFF the power supply to all equipment to be used before making connections.
Read the Instruction Manual for each piece of equipment to be used before making
connections.
The control signal cable cannot be used for loop connection.
TX+ A
TX B
RX+ C
RX D
TX+ A
TX B
RX+ C
RX D
TX+ A
TX B
RX+ C
RX D
RX+ A
RX B
TX+ C
TX D
RM-P2580
Connecting the control signal cable
(Use a twisted-pair cable for connection. See page 16.)
Connect:
Camera TX+ to RM-P2580 RX+
Camera TX to RM-P2580 RX
Camera RX+ to RM-P2580 TX+
Camera RX to RM-P2580 TX
The A B C D marks indicated on both the camera
terminals and the RM-P2580 terminals facilitate correct
connections. Connect the terminals with identical
marks.
Camera 1 terminal board
Camera 2 terminal board
Camera 3 terminal board
RX+ C
RX D
A TX+
B TX
Terminal board
Lug plates
DC 12 V or AC 24 V
power cable
To DC 12 V or AC 24 V power supply
Control signal cable
To Remote Control Unit (RM-P2580)
To Remote Control Unit (RM-P2580)
Video
signal cable