ALARM TITLE Setup
Use the ALARM TITLE screen to set the alarm titles to be displayed when an alarm signal is transmitted.
Up to 10 alarm titles (ALARM TITLE 1 to 10) can be set and each title can be up to 12 characters in length.
1.
Select the camera. (
RM-P2580 Instruction manual)
CAMERA button
Numeric key (camera number)
ENTER but-
ton.
The picture of the selected camera is output.
2.
Display the SETUP menu on the camera.
(
P. 20, steps
1
to
4
)
MENU button (3 sec.)
Select “CAMERA” with the PAN/TILT lever
SET button.
3.
Tilt the PAN/TILT lever up or down to move the cur-
sor (>) to “CAMERA TITLE/ALARM” and press the
SET button.
The TITLE/ALARM screen is displayed.
4.
Move the cursor (>) onto the item “ALARM TITLE
EDIT” and press the SET button.
The ALARM TITLE 1 menu is displayed.
The first characters in the character area and title input field blink
to indicate that the system is ready for a title input.
5.
Use the PAN/TILT lever to select the first character
of the title from the character area.
The character being selected blinks.
The selected character is displayed in the title input field.
6.
Press the TELE button.
The first character of the title is input, and the system gets ready
for the input of the second character.
If the WIDE button is pressed, the blinking position in the title in-
put field moves to the left. Use this facility to correct previously
input characters.
7.
Press the FAR button.
The next ALARM TITLE screen is displayed.
If the NEAR button is pressed, the previous ALARM TITLE screen
is displayed.
8.
Repeat steps
5
to
7
for each alarm title.
Complete the input of all the alarm titles (ALARM TITLE 1 to 10) in
this way.
9.
Press the MENU button.
• The screen returns to the previous menu.
RM-P2580 units need to be configured to display Alarm Titles. Use the RM-P2580 menu settings
to do this:
1. Press and hold the MENU button for 3 seconds to display the SETUP screen on the remote control unit.
2. First select the CONTROL UNIT screen, then the DATA I/O screen and finally the INPUT ASSIGNMENT screen.
3. Select “ALARM TEXT” then “EDIT 1”, the alarm title set as ALARM TITLE 1 is displayed on the monitor.
* The alarm signals are input into the DATA I/O terminals on the rear panel of the RM-P2580.
SETUP
MENU SET
SPEED
IRIS
AF
FOCUS
ZOOM
OPEN
FAR
TELE CLEAR
/HOME
7
4
1
8
0
5
2
9
6
3
ENTER
AUTO
PAN
OPTION
1
OPTION
2
CAMERA
POSI-
TION
AUTO
PATROL
CLOSE
NEAR
WIDE
AUTO F-1 F-2 F-3
PAN/TILTLENS
CAMERA/POSITION
CAMERA POSITION
REMOTE CONTROL UNIT
RM-P2580
ALARM
POWER
KEY LOCK
PAN/TILT
lever
CAMERA
buttons
WIDE button
FAR button
TELE button
NEAR button
ENTER button
SET button
MENU button
SETUP menu display on the camera
CAM. FUNCT ION1 . .
CAM. FUNCT ION2 . .
–––MENU–––
CAM. TITLE/ALARM. .
CAM. VIDEOADJUST. .
CAM. ALC. .
HOME MOTION DETECT . .
AUTO PAN/PATROL/TRACE. .
POSI .FUNCTION SET. .
FACTORY SETTINGS. .
TITLE/ALARM menu
CAM.TITLE EDIT. .
–––CAMERA TITLE/ALARM
–––
AREA TITLE OFF
AREA TITLE EDIT. .
ALM.TITLE SIZE DOUBLE
ALM.TITLE COLOUR WHITE
ALARM TITLE EDIT. .
ALARM INPUT. .
ALARM OUTPUT. .
0123456789ABCDEFGHIJK
–––ALARM TITLE 1– ––
LMNOPQRSTUVWXYZ
abcdefg
hijklmnopqrstuvwxyz., '
–:/ÄÖÜÂÊÎÔÛÇÑäëï öüâêîô
ûáéíóúàèìòùçñß¡¿
TITLE NO.SELECT
FOCUS
WIDE TELE
Character area
ALARM TITLE screen
Title input
field
Blinking
Space Blinking