Olympus PT-E05 Camera Accessories User Manual


 
EN 12
En
Connecting the underwater optical fiber cable
Removing the TTL connector cap
To perform TTL flash shooting by connecting the separately available underwater flash or other products
to the Case using the underwater TTL cable (optional), remove the TTL connector cap as described
below.
How to attach the TTL connector cap to the case
Make sure there is no foreign matter attached to the O-rings inside the cap and on the TTL cable
connector. To secure the cap, gently turn it clockwise until it stops.
To connect the separately available UFL-2 underwater
flash to the Case using an underwater optical fiber cable
(optional), follow the procedures below.
Remove the cap of the optical fiber cable insertion slot.
Put the underwater optical fiber cable plug all the way
into the optical fiber cable insertion slot.
1 Remove the TTL connector cap from
the Case.
2 Connect the underwater TTL cable
(optional) to the TTL connector on the
Case.
CAUTION:
If the TTL connector cap is loose, water penetration may result. Be sure to gently turn the cap until it stops to
make sure it is firmly secured.
Do not turn or tighten the TTL cable too hard. If it is too tight, it may be difficult to loosen and remove.
1 Turn counter
clockwise.
TTL connector cap
2 Remove.
Underwater TTL
cable
Use this mark to
align the position.
3 Insert into the
connector.
4 Turn the threaded
section of the
connector clockwise
lightly until it stops.
Check O-rings
Cap Connector
2 Gently turn the cap
clockwise until it
stops.
1 Attach the cap to
the case.
PT-E05_EN.Book Page 12 Tuesday, June 17, 2008 11:11 AM