Insert the silica gel
Before sealing the Case, be sure to insert the silica gel bag in the space between the bottom of the
camera table and the inner surface of the Case. This will prevent fogging. Inset the silica gel bag laterally
with the sides folded down.
Check the loading status
Always perform the following final checks before sealing the Case.
Does the zoom dial operate properly?
Is the silica gel inserted all the way at the specified position?
Are the O-rings and the O-ring contact surfaces free of dirt and other foreign matter?
Are the O-rings installed properly?
Is the Waterproof Port attached correctly?
Is the TTL connector cap attached properly without loosening?
Can the camera power be switched ON/OFF?
Is the mode dial of the camera controllable?
When using an external electronic flash with a TTL cable, check that the hot shoe cable is connected
properly and that the camera’s automatic pop-up setting is set to OFF.
When using the UFL-2 underwater electronic flash with the underwater optical fiber cable, or when
using a slave flash from a non-Olympus manufacture, check that the camera's built-in flash is popped
up.
CAUTION:
Insert the silica gel bag as far as it will go at the specified location and with the specified orientation. If the
orientation is incorrect, the silica gel bag will get caught when the Case is sealed and water will leak into
the Case.
If the bag is only inserted part of the way, it will get caught by the O-ring when you try to seal the Case and
water will leak into the Case.
Once silica gel has been used, the moisture absorption performance will be impaired. Always change the
silica gel when you open or close the Case.
Pay attention to the orientation.