Panasonic AJ-HDX900E Camcorder User Manual


 
127
7
Chapter 7 Menu description tables
(continued)
PROPAC14
2
O
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2 : The selection is enabled.
O: The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL:The voltage is set manually.
11.0
:
13.8
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
7-8-3 BATTERY SETTING1
Item
Variable
range
Remarks
CUF
DIONIC90
2
O
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2 : The selection is enabled.
O: The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL:The voltage is set manually.
11.0
:
13.6
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
Item
Variable
range
Remarks
CUF
DIONIC160
2
O
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2 : The selection is enabled.
O: The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL:The voltage is set manually.
11.0
:
13.1
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
CUF
NP-L7
2
O
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2 : The selection is enabled.
O: The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL:The voltage is set manually.
11.0
:
12.9
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
CUF
ENDURA7
2
O
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2 : The selection is enabled.
O: The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL:The voltage is set manually.
11.0
:
13.2
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
CUF
TRIMPAC14
2
O
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2 : The selection is enabled.
O: The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL:The voltage is set manually.
11.0
:
13.6
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
HYTRON50
2
O
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2 : The selection is enabled.
O: The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL:The voltage is set manually.
11.0
:
13.2
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
CUF
CUF
HYTRON120
2
O
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2 : The selection is enabled.
O: The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL:The voltage is set manually.
11.0
:
13.0
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
CUF
The underlining in the variable range column indicates the setting in the preset
mode.
O When the digital battery is attached in the unit, the
remaining capacity of the battery is displayed in percent.