4. Set the alarm action:
a. Use the joystick to position the cursor beside ALARM ACTION.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view the available selections. The following are the settings for alarm action:
NONE: No action when alarm is triggered.
PRESET: Dome goes to the preset that is the same as the alarm number. Preset 1 will go to Alarm 1.
PATTERN 1: Dome runs pattern 1 when alarm is triggered.
PATTERN 2: Dome runs pattern 2 when alarm is triggered.
PATTERN 3: Dome runs pattern 3 when alarm is triggered.
PATTERN 4: Dome runs pattern 4 when alarm is triggered.
PATTERN 5: Dome runs pattern 5 when alarm is triggered.
PATTERN 6: Dome runs pattern 6 when alarm is triggered.
PATTERN 7: Dome runs pattern 7 when alarm is triggered.
PATTERN 8: Dome runs pattern 8 when alarm is triggered.
AUTO SCAN: Dome starts auto scan operation when alarm is triggered.
RANDOM SCAN: Dome starts random scan operation when alarm is triggered.
FRAME SCAN: Dome starts frame scan operation when alarm is triggered.
d. Press Iris Open to enter selection.
5. Set the auxiliary to activate:
a. Use the joystick to position the cursor beside ACTIVATE AUX.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view the following available selections.
NO (default): Not activated.
1: An alarm action will close AUX 1.
2: An alarm action will close AUX 2.
d. Press Iris Open to enter selection.
Note: The AUX 1/AUX2 will stop when all the alarms assigned to it have cleared. If the AUX1/AUX is set up as momentary, then it will be