Pelco C1302M-F (11/08) Security Camera User Manual


 
18 C1302M-F (11/08)
Maintenance
CAMERA MODULE REPLACEMENT
To replace the camera module do the following:
1. Remove the back cap of the camera enclosure. Refer to Figure 12 and do the following:
a. Loosen the set screw with a 1.5 mm Allen wrench.
b. Use the supplied spanner wrench to loosen the back cap of the camera enclosure. Once the back is loose, use your hands to continue
to loosen it until it can be removed.
Figure 12. Remove Back Cap of Camera Enclosure
2. Remove the 8-32 Phillips flat head screw that secures the camera module inside the enclosure, refer to Figure 13.
Figure 13. Remove or Install Camera Module
DANGER: To reduce the risk of ignition of hazardous atmospheres, disconnect the equipment from the power supply before opening.
Keep assembly tightly closed when operating.
CAMERA
ENCLOSURE
BACK
SPANNER
WRENCH
SET SCREW
BUSHING
SET TAB IN
CENTER POSITION
CAMERA
MODULE
HANDLE
8-32 PHILLIPS FLAT
HEAD SCREW
ARM
STUD