C2487M-A (4/05) 25
SCAN SPEED
Scan speed is the degrees per second that the dome will pan when in a scan mode. Scan speed
is adjustable from 1 to 40 degrees per second through the programming menu. The default
setting is 25 degrees per second.
PRESET FREEZE FRAME
This feature freezes the scene on the monitor when going to a preset. This allows for smooth
transition from one preset scene to another. Preset freeze frame also reduces bandwidth when
used with digital network systems such as PelcoNet
™
and guarantees that blanked areas will not
be revealed when going to a preset.
There are three preset freeze frame settings:
ON The image on the screen freezes when a preset is called. When the dome
reaches the preset, the image is unfrozen and the preset scene is
displayed.
OFF The image is never frozen.
AUTO (default) Freeze frame is turned on automatically if window blanking is ON. If
window blanking is OFF, freeze frame is off.
MOTION
AUTO FLIP ON
PROPORTIONAL PAN ON
PARK TIME (MINUTES) 0
PARK ACTION NONE
SCAN SPEED (DEG/S) 25
PRESET FREEZE FRAME AUTO
LIMIT STOPS ON
<SET MANUAL STOPS>
<CLEAR MANUAL STOPS>
<SET SCAN STOPS>
<CLEAR SCAN STOPS>
<SET AZIMUTH ZERO>
<CLEAR AZIMUTH ZERO>
BACK
EXIT
REFERENCE INFORMATION
MANUAL LIMITS SET NO
SCAN LIMITS SET NO
BACK
EXIT
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<ALERT>*
<CLEAR>
<PASSWORD>
DOME SETTINGS
EXIT
SPECTRA III
LANGUAGE ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
(See page 9)
Quick Programming Guide
*This setting only applies to
Pressurized Spectra III dome
systems with software version