Pelco C2446M-D Security Camera User Manual


 
26 C2487M-A (4/05)
LIMIT STOPS
Limit stops are programmable stops that limit the pan range of the dome. There must be two
limits, a left and a right, to define an area.
There are two types of limit stops:
MANUAL A manual (joystick) pan operation stops when a limit stop is reached.
SCAN The dome reverses direction during random, frame, or auto scanning when a
limit stop is reached.
To set manual or scan stops:
1. Use the joystick to position the cursor beside SET MANUAL STOPS or SET SCAN
STOPS.
2. Press Iris Open.
3. Follow the directions displayed on the monitor.
NOTE: For the manual or scan stops to work, the LIMIT STOPS setting must be ON.
To clear manual or scan stops:
1. Use the joystick to position the cursor beside CLEAR MANUAL STOPS or CLEAR SCAN
STOPS.
2. Press Iris Open.
3. Follow the directions displayed on the monitor.
MOTION
AUTO FLIP ON
PROPORTIONAL PAN ON
PARK TIME (MINUTES) 0
PARK ACTION NONE
SCAN SPEED (DEG/S) 25
PRESET FREEZE FRAME AUTO
LIMIT STOPS ON
<SET MANUAL STOPS>
<CLEAR MANUAL STOPS>
<SET SCAN STOPS>
<CLEAR SCAN STOPS>
<SET AZIMUTH ZERO>
<CLEAR AZIMUTH ZERO>
BACK
EXIT
REFERENCE INFORMATION
MANUAL LIMITS SET NO
SCAN LIMITS SET NO
BACK
EXIT
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<ALERT>*
<CLEAR>
<PASSWORD>
DOME SETTINGS
EXIT
SPECTRA III
LANGUAGE ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
*This setting only applies to
Pressurized Spectra III dome
systems with software version
1.27 or higher.