C2443M-D (11/05) 37
Alarms
The Spectra III SE dome has seven alarm inputs, which can be programmed as high, medium or
low priority. When an alarm is received, an input signal to the dome triggers the user-defined
action (go to preset, run pattern, etc.) programmed for the alarm.
There are three global alarm settings:
RESUME This mode lets the dome resume its previous activity (scan,
pattern, or previous position) after all alarms are cleared.
SEQUENCE This is the time the dome will perform an alarm activity when
more than one alarm of the same priority occurs at the same time.
RESET DELAY This is the amount of time the dome considers the alarm to be
active after it has physically cleared.
Use the following steps to program alarm settings.
1. Use the joystick to position the cursor beside ALARM SETTINGS. Press Iris Open.
2. Select the alarm number:
a. Use the joystick to position the cursor beside ALARM NUMBER.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view selections. Press Iris Open to enter selection.
(Continued on next page)
BACK
EXIT
RESUME OFF
SEQUENCE (SECS) 5
RESET DELAY (SECS) 0
<ALARM SETTINGS>
ALARMS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
BACK
EXIT
DOME SETTINGS
(See page 11)
Quick Programming Guide
EXIT
SPECTRA III
LANGUAGE ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
BACK
EXIT
ALARM NUMBER 1
ALARM PRIORITY LOW
ALARM ACTION NONE
ACTIVATE AUX NO
ALARM CONTACT N/O
ALARM SETTINGS
* This setting only applies to
Pressurized Spectra III SE dome
systems with software version
1.25 or higher.