Pelco DD53M22-X Security Camera User Manual


 
38 C2443M-D (11/05)
3. Select the alarm priority:
a. Use the joystick to position the cursor beside ALARM PRIORITY.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view the available selections. Available settings
include HIGH, MEDIUM, and LOW (default). If multiple alarms with different
priorities are active at the same time, the dome will only go to the alarms with the
highest priority.
d. Press Iris Open to enter selection.
HIGH Alarm action takes highest priority and will override
manual pan, tilt, and zoom control.
MEDIUM/LOW Alarm action will not occur if an alarm occurs during
manual pan, tilt, and zoom control.
4. Set the alarm action:
a. Use the joystick to position the cursor beside ALARM ACTION.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view the available selections. The following are
the settings for alarm action:
NONE No action when alarm is triggered.
PRESET Dome goes to the preset that is the same as the
alarm number. Preset 1 will go to Alarm 1.
PATTERN 1 Dome runs pattern 1 when alarm is triggered.
PATTERN 2 Dome runs pattern 2 when alarm is triggered.
PATTERN 3 Dome runs pattern 3 when alarm is triggered.
PATTERN 4 Dome runs pattern 4 when alarm is triggered.
AUTO SCAN Dome starts auto scan operation when alarm is
triggered.
RANDOM SCAN Dome starts random scan operation when alarm is
triggered.
FRAME SCAN Dome starts frame scan operation when alarm is
triggered.
d. Press Iris Open to enter selection.
BACK
EXIT
RESUME OFF
SEQUENCE (SECS) 5
RESET DELAY (SECS) 0
<ALARM SETTINGS>
ALARMS
EXIT
SPECTRA III
LANGUAGE ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
BACK
EXIT
DOME SETTINGS
* This setting only applies to
Pressurized Spectra III SE dome
systems with software version
1.25 or higher.
BACK
EXIT
ALARM NUMBER 1
ALARM PRIORITY LOW
ALARM ACTION NONE
ACTIVATE AUX NO
ALARM CONTACT N/O
ALARM SETTINGS