Pelco DD53M22-X Security Camera User Manual


 
40 C2443M-D (11/05)
Aux
An auxiliary output is a programmable signal from the dome back box that can trigger another
device to operate. An auxiliary output is programmable to trigger from an alarm or from a
controller.
An AUX 1 command from the controller will activate the relay in the dome and operate the
device that is connected to the relay. The output of AUX 1 can be connected to the alarm input of
a system switch to activate automatic monitor switching and recording.
An AUX 2 command from the controller will place a ground at the output of AUX 2 to operate the
device that is connected to it.
The following are the available AUX MODE settings:
TOGGLE (default) Changes the state of the auxiliary output every time an AUX
command is received from the controller.
LATCHING Must receive an AUX ON/AUX OFF command from the controller
to turn the auxiliary output on/off.
MOMENTARY An AUX ON command from the controller turns the auxiliary
output on for the programmed DWELL TIME. The auxiliary output
will automatically turn off when the dwell time is finished.
BACK
EXIT
AUX 1 MODE TOGGLE
DWELL TIME (SECS) 1
AUX 2 MODE TOGGLE
DWELL TIME (SECS) 1
AUX
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
BACK
EXIT
DOME SETTINGS
EXIT
SPECTRA III
LANGUAGE ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
* This setting only applies to
Pressurized Spectra III SE dome
systems with software version
1.25 or higher.