6 Pelco Manual C411M-D (1/96)
4.4 PAN/TILT ENCLOSURE MOUNTING
The EH66 enclosure can also be mounted to a pan/tilt
assembly in addition to the wall or pedestal/ceiling
mount.
To include the pan/tilt assembly in your configuration,
perform the following steps:
1. Select the appropriate mount (WM2000 for wall
mounting, PM2000/PM2010 for pedestal mount)
for the application.
2. Select the appropriate pan/tilt for the application.
Considerations must be made as to enclosure op-
tions, camera and lens selection, and environmen-
tal conditions. All of these will affect the pan/tilt
selection.
3. Secure the mount to a suitable load bearing surface.
Use fasteners with a minimum 1/4-inch diameter.
4. Attach the pan/tilt to the mount. The pan/tilt control
connect should be positioned towards the building/
mounting location. Note the “front” label on the
pan/tilt.
5. If you have not already done so, install the
camera/lens according to the instructions in
Section 4.2 of this manual.
6. Balance the enclosure/camera/lens load on the tilt
table. Adjust the positioning as needed to align the
mounting holes. A minimum of two 1/4-20 x 5/8"
fasteners must be used. Secure the enclosure to the
tilt table.
7. Make all necessary electrical connections. Be sure
to leave an adequate loop of cables between the
enclosure and the pan/tilt, and the enclosure and the
rigid mount to prevent binding and/or strain on the
cables (see Figures 5 and 6).
Figure 5. EH66 Enclosure with Pan/Tilt and
Wall Mount
Figure 6. EH66 Enclosure with Pan/Tilt and
Pedestal/Ceiling Mount