Pelco Manual C411M-D (1/96) 7
4.5 WINDOW WIPER INSTALLATION
To install the window wiper kit, perform the following
steps and refer to Figures 7 and 8:
1. Turn the EH66 enclosure over so the bottom is
facing up.
2. If necessary, lay out the locations of the four (4)
.171-inch diameter mounting holes using the di-
mensions given in Figure 8.
4. Attach the wiper box using the four (4) mounting
holes, inserting the wire leads through one of the
rubber grommets.
5. Adjust the force of the wiper blade against the
glass by applying force to the arms toward the
glass or away from glass.
6. Attach wiper wire leads inside the enclosure as
shown in Figure 2.
7. Connect cable to wiper box.
8. Attach the water reservoir bottle to the rear of the
EH66 enclosure by removing the two (2) top acorn
nuts.
9. Place the bottle mount on the protruding studs and
replace the acorn nuts.
10. Attach the water hose to the bottle from the wiper.
Figure 8. Mounting Hole Dimensions
Figure 7. Window Wiper Motor Installation