Pelco Manual C411M-D (1/96) 13
8.0 OPTIONAL ACCESSORIES
FACTORY INSTALLED
EHRC Relay module for low voltage control
of wiper/washer and camera on/off.
Requires MEH24DT control module.
TI66 Thermal insulation provides increased
thermal protection for enclosure and
contents at extreme temperatures (for
model EH66 series only).
T166X Thermal insulation for model EH66X
series.
WD66 Window defroster and defogger, 120
VAC, 80 watt operation, prevents ice
buildup or condensation of moisture
on the window caused by temperature
and humidity. Must be used with heater/
blower assembly.
WD66/220 Same as WD66 except 230 VAC, 80
watt operation.
WW66 Window wiper and washer assembly,
120 VAC operation, designed to re-
move moisture and dirt from the win-
dow by remote control. The washer
enhances cleaning ability of wiper and
has a one quart reservoir for water or
antifreeze solution, which is recom-
mended for low temperature applica-
tions.
WW66-5/220 Same as WW66 except 230 VAC, 50 Hz.
FIELD INSTALLED
B66KIT Blower kit, 105 CFM, 13.4 watts at 60
Hz, 120 VAC, for EH66/EH66X en-
closures.
BK66KIT/220 Blower kit, 90 CFM, 15 watts at 50
Hz, 230 VAC, for EH66/EH66X en-
closures.
E624HB Heater/blower kit, 24 VAC, for Mod-
els EH66/EH66X.
EHCM Cradle mount for inverted mounting of
enclosure when used with PM2000/
AH2000 ceiling mount or pan and tilts.
H66KIT Heater kit, 120 VAC, for EH66/EH66X
enclosures. (For 230 VAC option, wire
heaters in series.)
L66KIT Tamper proof lock kit.
S66 Sun shroud, provides an air space be-
tween the sun shroud and the enclosure
to protect the enclosure from the direct
rays of the sun. Reduces internal tem-
perature approximately 10-15° (for
model EH66 only).
S66X Sun shroud for model EH66X.
MISCELLANEOUS
EB1 Elevation block 1", required for cam-
eras having a low optical centerline or
using a large diameter lens.
EB2 Elevation block 2", same as EB1, ex-
cept 2" high.
NOTE: Fasteners to secure mounts are not sup-
plied. (Minimum 1/4" diameter recommended.)
9.0 SPECIFICATIONS
ELECTRICAL
Input Voltage: 120 VAC, 60 Hz (230 VAC
optional)
Electrical
Connection: 6-pin terminal strip
GENERAL
Construction: 5052H32 aluminum
Finish: Polyester powder coat
Weight: EH66 — 11 lbs (4.98 kg)
EH66X — 14 lbs (6.34 kg)
Dimensions: See Figure 1
Cable Entry: Two adjustable 1/2" sealable
glands, mounted on removable
plate for ease of assembly.
Latches: Link lock fasteners
Window: 1/4" thick plate glass
Camera Mounting: Adjustable rail/sled