DISPLAY DURATION
Display Duration programs the duration the Az/El, Direction, and Zoom labels are displayed
on the monitor. The available settings for display duration include the following:
CONSTANT - The label is displayed continuously.
2 SECONDS (default) - The label is displayed for 2 seconds after PTZ functions
end.
5 SECONDS - The label is displayed for 5 seconds after PTZ functions end.
10 SECONDS - The label is displayed for 10 seconds after PTZ functions end.
To program the display duration for the Az/El, Direction, and Zoom labels:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Other.
3. Press the Iris Open button to enter the Other menu.
4. Position the cursor (>) beside Az/El/Direction.
5. Press the Iris Open button to enter the Az/El/Direction menu.
6. Position the cursor (>) beside Disp Duration.
7. Press the Iris Open button. The cursor moves to the right.
8. Move the joystick up or down to view the available selections.
9. SELECT – Press the Iris Open button to make a selection.
CANCEL – Press the Iris Close button to cancel selection.
Other Menu
Park Time 0
Pan/Scan Spd 7
Power Up Default
Pat length 6 min
Spd Profile 50 MPH wind
<Zone Blank>
<Az/El/Direction>
Exit
Az/El/Direction
Set Azimuth Zero
Az/El
Az/El Line
Direction
Direction Line
Disp Duration
Exit
MAIN MENU
<Limit Stop>
<Other>
EXIT