Pelco ES3012 Security Camera User Manual


 
Pelco Manual C306M-K (4/05) 27
POWER-UP MODE
This feature lets the system resume a desired condition following power-up. The menu in-
cludes the following choices.
Default - On power-up, the pan and tilt goes through a configuration cycle and stops at
zero reference, showing “Configuration Done,” address, and mode settings on the screen.
Park - The pan and tilt moves to preset 1 when the power-up sequence finishes. The
only text on the screen is the preset label (if any is programmed).
Scan Auto - The pan and tilt initiates scan mode when the power-up sequence fin-
ishes. Again, there is no text.
Scan Frame - The pan and tilt initiates a frame scan when the power-up sequence
finishes.
Scan Rand - The pan and tilt initiates a random scan when the power-up sequence
finishes.
Full Pat - The pan and tilt initiates its programmed pattern when the power-up se-
quence finishes. The length can be set to 1.5, 3, or 6 minutes.
Half Pat 1 - The pan and tilt initiates the first half-pattern when the power-up se-
quence finishes. The length can be set to .75, 1.5, or 3 minutes.
Half Pat 2 - The pan and tilt initiates the second half-pattern when the power-up se-
quence finishes. The length can be set to .75, 1.5, or 3 minutes.
The default setting is Default.
To select the power-up mode:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Other.
3. Press the Iris Open button to enter the Other menu.
4. Position the cursor (>) beside Power Up.
5. Press the Iris Open button to enter the Power Up menu.
6. Press the Iris Open button to move the cursor to the right.
7. Move the joystick up or down to cycle through the selections. Stop on the item you
want to select.
8. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.