Profoto Pro-7 Camera Accessories User Manual


 
Connect the generator to the mains supply with the enclosed power cable [1]. The green lamp
[3] should now light up indicating acceptable AC current to the generator.
• Connect the desired lamp heads to the sockets A, B1 & B2 [2].
• Use the control [15] marked MOD.LIGHT to choose modelling light mode.
• Press the button [4] marked ON to start charging. The white ready lamp [11] will light up
when the generator is fully charged.
Choose energy distribution. For socket A use dial A [5]. For the sockets B1 and B2 use dial B [7].
• Choose the desired energy with the energy control [6]. For full energy choose MAX.
• Connect sync cord and/or flash meter to the sync sockets [9] SYNC.
• Activate the photocell [8] by pressing the button [10] SLAVE
• Activate the audible signal by pressing the button [12] SOUND
• Choose fast recharging by pressing the button [13] FAST
• For extra fast recharging choose the button [14] TURBO
Mains (AC) Connection
Use the included power cable to connect at [1]. The Pro-7 can be connected to all common
mains voltages 90 - 240 Volt, 50-60 Hz. The generator automatically senses which voltage
range is supplied. The green lamp below the handle indicates that the generator is receiving
power from the mains. If not check the mains fuse for faults.
(Please also see ”Gas Generator” on page 24).
Warning: Never use ordinary household extension cords to elongate the power cable.
Connecting Lamp heads
One, two or three lamp heads can be connected to the sockets marked A, B1 and B2 [2]. When
connecting the lamp head plug, align the white dots on the plug with the white dot on the gener-
ator panel. Secure by turning the locking ring on the plug clockwise.
Brief Instructions
Pro-7a 1200/2400 Generator
16