32
Pro-7s/1200 Pro-7s/2400
Guide numbers in metres/feet at 100 ASA
with a Magnum 50° Reflector 140 201
Flash Duration (t 0.5) at:
Pro-7 head Pro-7 twin Pro-7 head Pro-7 twin
4800 Ws – – – 1/1600 sec.
2400 Ws – 1/2200 sec. 1/1600 sec. 1/2200
1200 Ws 1/2200 sec. 1/3200 1/2200 1/3200
600 Ws 1/3200 1/5300 1/2700 1/4500
300 Ws 1/4500 1/6800 1/3200 1/5300
150 Ws 1/5300 1/8000 1/5300 1/8000
75 Ws 1/8000 1/12000 1/5300 1/8000
37,5 Ws 1/8000 1/12000 1/8000 –
18.75 Ws 1/12000 – – –
PLEASE NOTE: With Pro-7 twin and two Pro-7s generators the recharging time is approx. twice as fast.
Recharging Time at:
230V/50Hz 0.08 - 0.8 sec. 0.12 - 1.5 sec
120V/60Hz 0.10 - 0.9 0.14 - 1.6
200V/50Hz 0.08 - 1.1 0.12 - 2.1
100V/50Hz 0.14 - 1.6 0.18 - 2.9
P
ower Consumption (Turbo)
200 - 240V, 50/60Hz 10 A (fuse)/generator
100 - 120V, 50/60Hz 15 A (fuse)/generator
Maximum Modelling Light
Maximum 500 W per head or totally 1500 W when three heads are used. Please note that the
modelling light output automatically adjusts itself to the voltage in question (100 - 240V).
Size & weight, generators
Pro-7s/1200 Pro-7s/2400
Width x length x height cm/in 24 x 17 x32 24 x 17 x 40
9
1
/
2
x 6
3
/
4
x12 9
1
/
2
x 6
3
/
4
x 15
3
/
4
Weight, kg/lb 9 / 20 12 / 26
Size weight, lamp head
Length (incl. glass 26 x 10 cm
cover) x diameter, cm/in 10” x 4”
Weight, kg/lb 2.4 / 5
Gas Generator
Most gas generators with an output of 3000 W or more can always power Profoto generators.
Please note that you always need a ProGas unit between the gas generator and the Profoto gen-
erator in order not to damage these two units (only 230V). For more information please contact
your local dealer.
Technical Data Pro-7s