28/37
FV-G200B1
User’s Guide Rev. 1.01
Command No. Command Description
5EH:
CDS_BASEGAIN[7..0]
5FH:
CDS_BASEGAIN[15..8]
[CDS Base Gain] Initial data: CDS_BASEGAIN[15..0] = 368, data range: 0 to 1023
When the result of the below equation exceeds 1023, 1023 will be set
CDS_BASEGAIN[15..0] + PGA[7..0] x 2 + GOFS[7..0]
*PGA[7.0]: The CDS gain (The value of the address 30H)
*GOFS[7.0]: The gain offset (The value of the address 32H)
78H: TESTP[7..0]
[Test pattern selection] Initial data: TESTP[7..0] = 00H
Sets the test pattern output from the camera.
D[7..0]
D7 D6 D5 D4 D3 D2 D1 D0
D7 to D0: 00H: Video output 01H: Gray scale
02H: Ramp wave 03H: 100% white
04H: White clip 05H: Color bar (RGB Bayer)
Others: Black
79H:
EFFCT[7..0]
[Image effect selection] Initial data: EFFCT[7..0] = 00H
Sets the image effect.
D[7..0]
D7 D6 D5 D4 D3 D2 D1 D0
D7: Negative / Positive video selection 0: Positive image 1: Negative image
D6 to D0:
Image effect 00H: No effect (Original) 01H: 9bit gradation
02H: 9bit gradation 03H: 7bit gradation
04H: 6bit gradation 05H: 5bit gradation
06H: 4bit gradation 07H: 3bit gradation
08H: 2bit gradation 09H: 1bit gradation
0A to 7FH: No function
(Prohibited settings. Do not set these values)
80H: E2P[7..0]
[EEPROM control] Initial data: E2P[7..0] = 00H
D[7..0]
D7 D6 D5 D4 D3 D2 D1 D0
D7 to D1:
No function Always set as “0000000”
D6 to D0:
Write control to the EEPROM 0: Prohibited 1: Accept
Note: This bit is cleared to “0” automatically by the internal processes after the execution of the command.