Ricoh FV-L200B1 Digital Camera User Manual


 
5/32
FV-L200B1
User’s Guide Rev. 1.01
2 Camera Output Timing Charts
2.1 Normal Mode (Setting 10H: 1XX0XXXX)
Normal Full Scanning Partial Full Scanning 1/2 Partial Scanning 1/4 Partial Scanning
Clock
Speed
(MHz)
Normal x1/2
x1/4 Normal x1/2 x1/4 Normal x1/2 x1/4 Normal x1/2 x1/4
Frame
Rate
(Hz)
15.3 7.6 3.8 15.4 7.7 3.9 30.6 15.3 7.7 61.3 30.6 15.3
Clock Speed: 36.8181 MHz (Normal), 18.40905 MHzx1/2, 9.204525 MHzx1/4
2.1.1 Horizontal Timing
1 CLK = 108.6422 ns at 3.8fps
1 CLK = 54.3211 ns at 7.6fps
1 CLK = 27.1605 ns at 15.3fps
300 CLK1620 CLK
Video out
LVAL
DVAL
Horizontal blanking
1920 CLK
One horizontal (1H)
1620 CLK300 CLK
300 CLK
Video output
300 CLK
93
CLK
207 CLK
FVAL